Sign In Join Help
 
ShenzhenN-netTechnologyCo.,Ltd

 
 
Recommended Results 
 
Industrial hybrid power over ethernet switch 

  Category : Textiles and clothing->Accessories->handbag accessories

     
Industrial hybrid power over ethernet switch
       

  Product Specification
 
  Model No:      NT-IN1082GF-8POE
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
<p class="MsoNormal">
Overview
</p>
<p class="MsoNormal">
NT-IN1082GF&nbsp;series is&nbsp;10-port industrial Ethernet unmanaged switch,&nbsp;providing&nbsp;2 Gigabit Ethernet 1000Base-X ports and up to 8 100Base-TX ports. Up to 3Mb large volume buffer makes ideal for applications that require high-bandwidth data transmission.
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NT-IN1082GF&nbsp;series provides&nbsp;12~48Vdc or 24Vac redundant power inputs, with rugged IP30 grade metal housing, DIN-Rail mounting or wall mounting, and high level EMI/EMC capability. NT-IN1082GF&nbsp;series is functional under a wide range of temperature from&nbsp;-40℃&nbsp;to 80℃. All of these features make the switches ideal for applications that require high-bandwidth transmission for uplink, such as video surveillance, tolling system, wireless access and factory automatic.
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;NT-IN1082GF&nbsp;series complies&nbsp;with IEEE 802.3at High Power over Ethernet technology&nbsp;(optional). It is backward compatible with 802.3af PSE&nbsp;standards to allow users flexibly deploy standard and high powered devices simultaneously with no need of software configuration. With Data and Power over Ethernet from one unit, NT-IN1082GF&nbsp;series shall reduce cables deployment and eliminate the need for dedicated electrical outlets on the wall, ceiling or any unreachable place.
</p>
<p class="MsoNormal">
Features
</p>
<p class="MsoNormal">
Built-in efficient switching core to implement flow control and reduce broadcast packets
</p>
<p class="MsoNormal">
Standard:
</p>
<p class="MsoNormal">
IEEE802.3u 100BASE-TX. IEEE802.3 10BASE-T. IEEE802.3x Flow Control.
</p>
<p class="MsoNormal">
IEEE802.3z 1000Base-X. IEEE802.3at PSE. IEEE802.3af PSE
</p>
<p class="MsoNormal">
Supports 2 gigabit SFP slots for uplink&nbsp;and&nbsp;8&nbsp;10/100M copper ports
</p>
<p class="MsoNormal">
Automatically identify the direct line and cross-line, is compatible with Various NICs, switches, HUB and other Ethernet devices
</p>
<p class="MsoNormal">
It uses a store-and-forward mechanism to avoid packet loss and error frames
</p>
<p class="MsoNormal">
Support full-duplex flow control / half-duplex back pressure mode
</p>
<p class="MsoNormal">
Support jumbo frame up to 1536 Byte
</p>
<p class="MsoNormal">
Ideal for any complex network environment&nbsp;with 3Mb data buffer and 8.8G non-blocking switch fabric
</p>
<p class="MsoNormal">
12V to 48V DC or 24V AC Wide power input, redundant power and reverse polarity protection
</p>
<p class="MsoNormal">
-40 To 80&nbsp;℃ operating temperature to meet a variety of complex environments
</p>
<p class="MsoNormal">
IP30 protection standard housing
</p>
<p class="MsoNormal">
Power port and Ethernet port supports ESD protection and EFT protection
</p>
<p class="MsoNormal">
DIN rail and&nbsp;wall&nbsp;mounting for efficient usage
</p>
<p class="MsoNormal">
Support dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode fiber port selection, expanded the needs of users
</p>
<p class="MsoNormal">
Support POE power supply up to 25.5W(optional)
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Specifications
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Parameter
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Design Level
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Industrial grade IP30 design standards
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Access mode
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100/1000Mbps
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Standard
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX, IEEE802.3z 1000Base-X,
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3x Flow Control,&nbsp;IEEE802.3at PSE,&nbsp;IEEE802.3af PSE
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Wavelength
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
850nm/1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Transmission distance
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Dual-fiber multi-mode:2 km
</p>
<p class="MsoNormal">
Dual-fiber single&nbsp;mode:20/40/60/80/100 km
</p>
<p class="MsoNormal">
Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Port
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RJ45 ports:&nbsp;Connecting STP/UTP category-5 twisted pairs, EIA568A/B
</p>
<p class="MsoNormal">
Gigabit SFP ports: depending&nbsp;on SFP module
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Switch Architecture
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Store and Forward
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Switch Fabric
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
8.8G/Non-blocking
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Address table
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
4K
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Buffer space
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Built in 3Mb&nbsp;RAM for data buffer
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Flow control
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Full duplex: flow control; Half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;BER
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MTBF
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
50,000 hours
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;LED indicator
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Power Supply : PWR 1&nbsp;, PWR 2
</p>
<p class="MsoNormal">
UTP Port: POE, L/A ,100
</p>
<p class="MsoNormal">
Fiber Port: L/A
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power supply
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Power Input Range: 12 ~ 48VDC/24VAC ,6-PIN Terminals, Redundant&nbsp;dual power
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power consumption
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&lt;10W
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;PoE Power Pins
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;RJ45: &nbsp;Mode A -- pins 1 and 2 for PoE(+); 3 and 6 for PoE(-)(Default)
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Mode B -- pins 4 and 5 for PoE(+); 7 and 8 for PoE(-)(Optional)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
-40~80ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage Temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
-40~85ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dimensions
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
155mm (W)×125mm (D)×50 mm (H)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Weight
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Certification
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="661" valign="center" colspan="2">
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;Certification
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMI
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC Part 15, CISPR (EN55022) class A
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMC
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC,CE
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMS
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-2 (ESD), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-3 (RS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-4 (EFT), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-5 (Surge), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-6 (CS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-8, Level 5
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-11
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Shock
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-27
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Free Fall
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-32
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-6
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Green product
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;RoHS
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Application
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/58/c3/ac/2af47087c3498d1a74e832b6f9.png@" width="436" height="316" title="industrial ring network POE switch" alt="industrial ring network POE switch" />
</p>
<p class="MsoNormal">
Dimensions
</p>
</p>
<p>
<img src="http://i.bosscdn.com/product/93/a0/9c/95bbb0ee2fffcc2b2dc7dce1f1.png@" width="4408" height="2368" title="industrial poe swicth" alt="industrial poe swicth" />
</p>nnetswitch.com

  More Products from this Supplier
 
HD-SDI digital HD video converter

HD-SDI digital HD video converter
fiber media converter 10g

fiber media converter 10g
Fast industrial POE switch

Fast industrial POE switch
Gigabit SFP Media Converter

Gigabit SFP Media Converter
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .