unmanaged fiber media converter 

  Category : Textiles and clothing->Accessories->handbag accessories

     
unmanaged fiber media converter
       

  Product Specification
 
  Model No:      NT-S1200
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
Overview
</p>
<p class="MsoNormal">
<br />
NT-1200&nbsp;series have 2 <span>10M/100Mbps self-adaptive ports,</span>converting&nbsp;the 2 independent 10Base-T or 100Base-TX twisted pair electrical signal with 100Base-FX optical signal. It extends the network transmission range of the <span>limit of copper line</span>&nbsp;from 100m, &nbsp;to 120Km (single mode full duplex). It supports two different types of network connection media, 10/100Base-TX and 100Base-FX. By switching technique and storage &amp; forwarding technique, it realizes the data transmission between two network connection media. It supports optical transmission under dual-fiber multi-mode, dual-fiber single mode, and single fiber single mode.
</p>
<p class="p">
&nbsp;
</p>
<p class="p">
Features
</p>
<p class="MsoNormal">
10/100Mbps auto-sensed, facilitating network upgrade
</p>
<p class="MsoNormal">
Built-in efficient switching core to implement flow control and reduce broadcast packets
</p>
<p class="MsoNormal">
Providing several respective 10M/100Mbps adaptive twisted pair switching ports which implement the backup of electrical ports and the access of multiple users
</p>
<p class="MsoNormal">
Supporting full-duplex and half-duplex and its auto-sensed
</p>
<p class="MsoNormal">
Supporting auto-sense of MDI/MDI-X, facilitating system commissioning and installation
</p>
<p class="MsoNormal">
Supporting the transmission of extra-long packets up to 1552 bytes
</p>
<p class="MsoNormal">
Low power consumption, reliable and stable performance;
</p>
<p class="MsoNormal">
Options in single mode in dual fiber, multi-mode in dual fiber, and single mode in single fiber
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Specifications
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Parameter
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Access mode
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Standard
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;IEEE802.3 10Base-T Ethernet,
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3u,100Base-TX/FX Fast Ethernet,
</p>
<p class="MsoNormal">
&nbsp;IEEE802.3x Flow control
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Wavelength
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;850nm/1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Transmission distance
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Multi-mode Dual-fiber: 2 km;
</p>
<p class="MsoNormal">
&nbsp;Single mode Dual-fiber: 20/40/60/80/100/120 km;
</p>
<p class="MsoNormal">
&nbsp;Single mode Single fiber: 20/40/60/80/100/120&nbsp;km
</p>
<p class="MsoNormal">
&nbsp;Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Port
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;RJ45 port:
</p>
<p class="MsoNormal">
&nbsp;Connecting with STP/UTP category-5 twisted pairs
</p>
<p class="MsoNormal">
&nbsp;Optical port:&nbsp;&nbsp;
</p>
<p class="MsoNormal">
&nbsp;Multi-mode: SC or ST (50, 62.5/125μm)
</p>
<p class="MsoNormal">
&nbsp;Single mode: SC or FC (9/125μm)
</p>
<p class="MsoNormal">
&nbsp;Single mode Single fiber: SC/FC (9/125μm)
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Flow control
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Full duplex: flow control; half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Error rate
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MTBF
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;100,000 hours
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;LED indicator
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;POWER (power supply); FX LINK/ACT (fiber link/action)
</p>
<p class="MsoNormal">
&nbsp;FDX (FX full duplex), FX100 (fiber rate 100M)
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power supply
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;DC5V 1A (external)
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power consumption
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;3.5W
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating temperature
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-10~55ºC
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating humidity
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90%
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Maintaining temperature
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~70ºC
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Maintaining humidity
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5% ~ 90% non-condensing
</p>
</td>
</tr>
<tr>
<td width="157" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dimensions
</p>
</td>
<td width="508" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;110mm(W)×82mm(D)×47mm(H) (external power supply)
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Application
</p>
<p class="MsoNormal" align="center">
<img src="http://i.bosscdn.com/product/a7/ce/c3/15d1e755a2814b3b1f3f21547e.png@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=29&p=9&t=80&text=bi1uZXQuYm9zc2dvby5jb20%3D" title="NT-1200" alt="NT-1200" />&nbsp;
</p>
<p class="MsoNormal" align="center" style="text-align:left;">
Order Information
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, multi-mode, 2km, SC, standalone,&nbsp;external power &nbsp;adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200S-25
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports,single mode, 25km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200S-40
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F,&nbsp;2TP ports,single mode, 40km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200S-60
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F,&nbsp;2TP ports,single mode, 60km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200S-80
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F,&nbsp;2TP ports,single mode, 80km, SC, standalone,external power adaptorr
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-1200S-100
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F,&nbsp;2TP ports,&nbsp;single mode, 100km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-S1200-25
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, WDM(single fiber bi-direction), 25km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-S1200-40
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, WDM(single fiber bi-direction), 40km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-S1200-60
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, WDM(single fiber bi-direction), 60km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-S1200-80
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, WDM(single fiber bi-direction), 80km, SC, standalone, external power adaptor
</p>
</td>
</tr>
<tr>
<td width="112" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-S1200-100
</p>
</td>
<td width="556" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
10/100Base-T to 100Base-F, 2TP ports, WDM(single fiber bi-direction), 100km, SC, standalone, external power adaptor
</p>
</td>
</tr>
</tbody>
</table>nnetswitch.com

  More Products from this Supplier
 
5-port Fast POE Ethernet switch

5-port Fast POE Ethernet switch
LCD 10/100M power over ethernet switch

LCD 10/100M power over ethernet switch
managed Ethernet switch 10/100/1000M

managed Ethernet switch 10/100/1000M
industrial 10/100m Ethernet switch

industrial 10/100m Ethernet switch
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .