EOC Ethernet to coax adapter 

  Category : Textiles and clothing->Accessories->handbag accessories

     
EOC Ethernet to coax adapter
       

  Product Specification
 
  Model No:      NT-EN1400
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<br />
</p>
<div class="Section0">
<p class="MsoNormal" align="justify">
v&nbsp;Overview
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400 is a device for Ethernet transmission over coax featuring Coax to UTP connectivity, equipped with one Ethernet port and four BNC ports, which can make a ring or aggregation. So it can be used in pair or one to multi.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
The equipment can transmit signal over all kinds of common cables such as telephone line, Ethernet cable, UTP or coax etc., with excellent isolation, thunder prevention and anti-jamming function. In the practical project, this device is proved to be of high performance in surge prevention. It transmits IP video or Ethernet up to 1.5km at a max rate 70Mbps over existing coax, thus cut the cost by avoid re-cabling when swapping analog cameras for IP/Megapixel models.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400-AT (AF) series is POE version of model NT-EN1400, it can supply power over Ethernet cable for PD devices like HD cameras, wireless AP, IP telephone equipment. Our EOC support IEEE802.3af (15.4W) and IEEE802.3at (25.5W) standard.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EN1400-AT (AF) series also supports POC (Power over Coax) function. Model at local side (namely the master) can supply power over coax cable for the model at remote side (the slave) and IP cameras.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
v&nbsp;Feature
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Modulation frequency: 2 MHz-28 MHz
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Modulation method: OFDM
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Encryption: AES128-bit encryption
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Networking: One Master and 7 Slaves
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Protocol:IEEE802.3/u 10Base-T, 100Base-TX, IEEE802.1Q VLAN, IEEE802.3af/at
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
* Support Auto-sensation of MDI/ MDIX at Ethernet port, compatible with NIC, switch and HUB etc.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support up to 1522Bytes data packet
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support Store and forward working mode; backpressure on Half-Duplex and flow control Full-Duplex.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Power supply range: DC 12V-56V
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Operation temperature: -20-70℃
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;Support Ethernet ESD protection and EFT
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal" align="justify">
*&nbsp;POE (15.4W) and POE+ (25.5W) supported (optional)
</p>
<p class="MsoNormal">
<br />
</p>
</div>
<p>
<br />
</p>
<div class="Section1">
<p class="MsoNormal">
Specification
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable">
<tbody>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal">
Parameter
</p>
</td>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
Specification
</p>
</td>
</tr>
<tr>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Design grade
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Commercial Grade
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Rate
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Protocol
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
IEEE802.3/u, 10Base-T, 100Base-TX, IEEE802.1Q VLAN, IEEE802.3af/at
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
Transmission distance
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
Coax(SVY75-5): 1.5Km(TCP/IP up to 70Mbps)
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Cat 5: 100m
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
Port
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
one RJ45: connected to STP/UTP cat 5
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
one BNC: Q9
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Flow control
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Duplex: flow control, Half Duplex: Backpressure
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
BER
</p>
</td>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
&lt;10-9
</p>
</td>
</tr>
<tr>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
MTBF
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
50,000 hours
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
PWR- power,
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" rowspan="2">
<p class="MsoNormal" align="center">
LED indicator
</p>
</td>
<td width="524" valign="bottom">
<p class="MsoNormal">
LAN- link/ Act,
</p>
</td>
</tr>
<tr>
<td width="524" valign="bottom" rowspan="2">
<p class="MsoNormal">
Coax- coax cable connection
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
MASTER- master device monitoring
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Power supply
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
Input range:12~56 VDC
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Power
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&lt;6W (when POE not working)
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Storage humidity
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
5%~90% Non condensation
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Working humidity
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
5%~90% Non condensation
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Working temperature
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
-20~70℃
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Storage temperature
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
-40~85℃
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Dimension
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
94mm×71mm×26mm
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal" align="center">
Weight
</p>
</td>
<td width="524" valign="bottom" style="border:1.0000pt solid #ECE9D8;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
<tr>
<td width="145" valign="bottom">
<p class="MsoNormal">
&nbsp;
</p>
</td>
<td width="524" valign="bottom">
<img src="http://i.bosscdn.com/product/e9/57/94/42ff8a96aec5fc54dfef82c228.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=29&p=5&t=80&text=bi1uZXQuYm9zc2dvby5jb20%3D" title="EOC" alt="EOC" /><br />
</td>
</tr>
</tbody>
</table>
</div>nnetswitch.com

  More Products from this Supplier
 
unmanaged 2 fiber POE switch

unmanaged 2 fiber POE switch
gigabit unmanaged industrial siwtch

gigabit unmanaged industrial siwtch
Ethernet and power over coxa converter

Ethernet and power over coxa converter
L2 10/100M poe switch

L2 10/100M poe switch
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .