Sign In Join Help
 
ShenzhenN-netTechnologyCo.,Ltd

 
 
Recommended Results 
 
8 fiber ports POE switch 

  Category : Textiles and clothing->Accessories->handbag accessories

     
8 fiber ports POE switch
       

  Product Specification
 
  Model No:      NT-IN118-4POE
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<strong>Overview</strong>
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;NT-IN118S-20 is Industrial Fast Ethernet Media Converter with 9&nbsp;ports. It supports 8&nbsp;port 10/100BASE-T and 1&nbsp;port 100Base-X.
</p>
<p class="MsoNormal">
&nbsp;&nbsp;NT-IN118S-20 is packaged in a compact IP40 case that allows either DIN rail or panel mounting for efficient usage of cabinet space.
</p>
<p class="MsoNormal">
&nbsp;&nbsp;NT-IN118S-20-AT (AF) series can support 4 ports POE function. Without power and wires, can power supply for HD IP Camera, wireless AP.IP phone and so on. Our POE unmanaged Fast Ethernet Media Converter support IEEE802.3at, 25.5W output.&nbsp;It supports single mode dual fiber.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<strong>Features</strong>
</p>
<p class="MsoNormal">
* Built-in efficient switching core to implement flow control and reduce broadcast packets<br />
* Standard::IEEE802.3u 100BASE-FX,IEEE802.3u 100BASE-TX. IEEE802.3 10BASE-T.
</p>
<p class="MsoNormal">
IEEE802.3x Flow Control. IEEE802.3at
</p>
<p class="MsoNormal">
* 10/100Base-TX can automatically identify the direct line and cross-line, is compatible with various cards, switches, HUB and other Ethernet devices.
</p>
<p class="MsoNormal">
* It uses a store-and-forward mechanism to avoid packet loss and error frames
</p>
<p class="17">
* Support 8&nbsp;standalone 10M/100Mbps&nbsp;Adaptive switched twisted-pair cable. Realize electricity back-up and mutil-user access
</p>
<p class="17">
&nbsp;&nbsp;&nbsp;&nbsp;* Support jumbo frame up to 1600Bytes
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;* Support cut-through transmission&nbsp;and full-duplex flow control / half-duplex back pressure mode
</p>
<p class="MsoNormal">
* 12V to 48V DC or 24V AC Wide power input, redundant power and reverse polarity protection
</p>
<p class="MsoNormal">
&nbsp;* -40 To 85℃&nbsp;operating temperature to meet a variety of complex environments
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;* IP40 protection standard housing
</p>
<p class="MsoNormal">
* Power port and Ethernet port supports ESD protection and EFT protection
</p>
<p class="MsoNormal">
* DIN rail and panel mounting for efficient usage
</p>
<p class="MsoNormal">
* Support dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode fiber port selection, expanded the needs of users
</p>
<p class="MsoNormal">
* Support POE power supply up to 25.5W (optional)
</p>
<p class="MsoNormal">
* Provide up to 4K MAC address entries and built in 1.25 Mb RAM
</p>
<p class="MsoNormal">
* Provide up to 4K MAC address entries and built in 1.25 Mb RAM
</p>
<p class="MsoNormal">
* Dual fiber single mode
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
&nbsp;<strong>&nbsp;</strong><strong>Specifications</strong><strong>:</strong>
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Parameter
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Design Level
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Industrial grade IP40 design standards
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Access mode
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;10/100Mbps
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Standard
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="17">
IEEE802.3u 100BASE-FX,IEEE802.3u 100BASE-TX. IEEE802.3 10BASE-T.
</p>
<p class="17">
IEEE802.3x Flow Control. IEEE802.3at
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Wavelength
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Transmission distance
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
&nbsp;Dual-fiber multi-mode:2 km
</p>
<p class="MsoNormal">
&nbsp;Dual-fiber single mode:20/40/60/80/100 /120 km
</p>
<p class="MsoNormal" align="center">
&nbsp;Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Port
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Eight RJ45 port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Connecting STP/UTP category-5 twisted pairs, EIA568A/B
</p>
<p class="MsoNormal">
&nbsp;Two optical port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Single-mode&nbsp;:SC / FC/LC
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Conversion means
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Store and Forward mode
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Address table
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;4K
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Buffer space
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;&nbsp;1.25 Mbit
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Flow control
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
Full duplex: flow control; Half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Delay
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;store-and-forward:9.6us
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
BER
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;MTBF
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
50,000 hrs
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;LED indicator
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;POE1 ( POE1 power on/off).POE2 ( POE2 power on /off).POE3 ( POE3 power on/off).
</p>
<p class="MsoNormal" align="center">
POE4 ( POE4 power on/off),(1~8)&nbsp;UTP Port: L/A ,100
</p>
<p class="MsoNormal" align="center">
&nbsp;&nbsp;PWR1(PWR1 power on/off) ,PWR2(PWR2 power on/off)
</p>
<p class="MsoNormal" align="center">
&nbsp;&nbsp;F1(F1 Link/transmission)
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Power supply
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Power Input Range: 12 ~ 48VDC/24VAC ,
</p>
<p class="MsoNormal">
6-PIN Terminals, Redundant dual power
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Power consumption
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
7W
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Storage humidity
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;5%~90% non-condensing
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Operating humidity
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;5%~90% non-condensing
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;Operating temperature
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&nbsp;-40~85℃&nbsp;
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Storage Temperature
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
-40~85℃
</p>
</td>
</tr>
<tr>
<td width="143" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Dimensions
</p>
</td>
<td width="524" valign="top" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
155mm×125mm×50mm (W×D×H)&nbsp;
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
<br />
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="661" valign="center" colspan="2">
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;<strong>&nbsp;Certification</strong>
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMI
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC Part 15, CISPR (EN55022) class A
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMC
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC,CE
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMS
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-2 (ESD), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-3 (RS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-4 (EFT), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-5 (Surge), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-6 (CS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-8, Level 5
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-11
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Shock
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-27
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Free Fall
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-32
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-6
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<strong>Application</strong>
</p>
<p class="MsoNormal">
<strong><img src="http://i.bosscdn.com/product/bb/94/00/7263721532155f1b774dcfc8ca.jpg@watermark=2&amp;color=I0ZGRkZGRg%3D%3D&amp;type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&amp;size=29&amp;p=5&amp;t=80&amp;text=bi1uZXQuYm9zc2dvby5jb20%3D" title="IN118" alt="IN118" /></strong>
</p>
<p>
<br />
</p>nnetswitch.com

  More Products from this Supplier
 
5-port Fast POE Ethernet switch

5-port Fast POE Ethernet switch
EOC Ethernet to coax adapter

EOC Ethernet to coax adapter
industrial 10/100/1000M ethernet switch

industrial 10/100/1000M ethernet switch
10/100M internal media converter

10/100M internal media converter
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .