Sign In Join Help
 
ShenzhenN-netTechnologyCo.,Ltd

 
 
Recommended Results 
 
Ethernet and power over coxa converter 

  Category : Textiles and clothing->Accessories->handbag accessories

     
Ethernet and power over coxa converter
       

  Product Specification
 
  Model No:      NT-EP1100
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Overview
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-EP1100 is a new device for Ethernet over coax&nbsp;featuring Coax to UTP connectivity. It supports&nbsp;1 channel IP Ethernet transmission&nbsp;over coax up to 500m.&nbsp;Its TCP network communication rate can reach max. 39Mbps&nbsp;[Down link&nbsp;(camera to receiver):36Mbps;&nbsp;Up link&nbsp;(receiver&nbsp;to camera):3Mbps].&nbsp;In the practical project, this device is proved to be of high performance in&nbsp;thunder prevention and anti-jamming. And it is widely used in IP surveillance and connection of any IP/Megapixel camera to existing Coax cabling infrastructures.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
&nbsp;Features
</p>
<p class="MsoNormal">
Upgrade any legacy CCTV system without the expense of re-cabling, use existing coax for transmission of IP video, swapping&nbsp;analogue cameras for&nbsp;IP/Megapixel models.
</p>
<p class="MsoNormal">
Support 10/100 Base-T Ethernet to be transmitted over&nbsp;coaxial&nbsp;cable.
</p>
<p class="MsoNormal">
One transmitter at remote end can support POE+(30W)&nbsp;to IP camera.
</p>
<p class="MsoNormal">
Up to 14 receivers&nbsp;at central housing can be rack-mounted to 2U chassis (NT-R14), connecting up to 14 cameras.
</p>
<p class="MsoNormal">
Status LEDs&nbsp;indicate power, link connectivity/&nbsp;activity&nbsp;for RJ45 and BNC ports.
</p>
<p class="MsoNormal">
Sub-industrial design, working temperature range -20~70℃.
</p>
<p class="MsoNormal">
High performance in&nbsp;thunder prevention and anti-jamming.
</p>
<p class="MsoNormal">
Q9 regular BNC video connector&nbsp;(crimp terminal&nbsp;optional)
</p>
<p class="MsoNormal">
Up to 500m over RG59, 350m over SYV75-3(64)
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Specifications
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="378" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Items
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Parameters
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="4">
<p class="MsoNormal" align="center">
Power
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Power supply
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
AC adaptor
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" rowspan="2">
<p class="MsoNormal" align="center">
Voltage range
</p>
</td>
<td width="141" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Transmitter
</p>
</td>
<td width="141" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Receiver
</p>
</td>
</tr>
<tr>
<td width="141" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
DC48-56V
</p>
</td>
<td width="141" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
DC5V~12V
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Power Consumption
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&lt;3W (each&nbsp;end)
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="3" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Ethernet interface
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Port
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
RJ45
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Signal type
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
10/100Base-Tx
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Transmission distance
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Up to 100m
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Coax interface
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Port
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
BNC
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" rowspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Transmission rate
</p>
</td>
<td width="73" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Total transmission rate(Max)
</p>
</td>
<td width="84" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Down link transmission rate(Max)
</p>
</td>
<td width="126" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Up link transmission rate(Max)
</p>
</td>
</tr>
<tr>
<td width="73" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
39Mbps
</p>
</td>
<td width="84" valign="center" colspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
36Mbps
</p>
</td>
<td width="126" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
3Mbps
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Transmission distance
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Up to 500m
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="2" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Protection level
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Transport channels surge protection
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
4KV(Common mode)<br />
Performance standard:IEC61000-4-5
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Whole electrostatic protection
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
1a&nbsp; Contact discharge&nbsp; 3&nbsp;grade&nbsp;<br />
1b&nbsp; Air discharge&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;3grade&nbsp;<br />
Performance standard: IEC61000-4-2
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="3" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Operating environment
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Operating temperature
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
0~55℃
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Maintaining temperature
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
-20~70℃
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Humidity(No condensation)
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
0~95%
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" rowspan="3">
<p class="MsoNormal" align="center">
Case
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Dimensions(Deep×Wide×Height)
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
94mmx 71mm x 26mm
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Shell
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Ferrous&nbsp;material
</p>
</td>
</tr>
<tr>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Color
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Black
</p>
</td>
</tr>
<tr>
<td width="194" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
Reliability
</p>
</td>
<td width="183" valign="center" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
MTBF
</p>
</td>
<td width="283" valign="center" colspan="4" style="border:1.0000pt outset windowtext;">
<p class="MsoNormal" align="center">
&gt;30000h
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Application
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/8c/b0/4f/4276decdefeaf478b953fcafb4.png@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=29&p=9&t=80&text=bi1uZXQuYm9zc2dvby5jb20%3D" title="NT-EP1100" alt="NT-EP1100" />
</p>
<p class="MsoNormal">
Order information
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="103" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal" align="center">
Model
</p>
</td>
<td width="560" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal" align="center">
Description
</p>
</td>
</tr>
<tr>
<td width="103" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-EP1100
</p>
</td>
<td width="560" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Receiver, without POE function, 1&nbsp;channel 10/100Mbps IP Ethernet transmission over Coax up to 500m,&nbsp;one coax port to one Ethernet port, input AC110-220V, output DC 5-12V
</p>
</td>
</tr>
<tr>
<td width="103" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
NT-EP1100-at
</p>
</td>
<td width="560" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Transmitter, with&nbsp;POE+(30W) to&nbsp;power&nbsp;the IP camera,&nbsp;1&nbsp;channel 10/100Mbps IP Ethernet transmission over Coax up to 500m,&nbsp;one coax port to one Ethernet port, &nbsp;input AC110-220V, output DC 48-56V
</p>
</td>
</tr>
</tbody>
</table>
<p>
<br />
</p>nnetswitch.com

  More Products from this Supplier
 
10/100/1000M LCD managed poe switch

10/100/1000M LCD managed poe switch
L2 managed fast power over ethernet switch

L2 managed fast power over ethernet switch
media converter with DIP Switch

media converter with DIP Switch
unmanaged industrial Ethernet siwtch

unmanaged industrial Ethernet siwtch
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .