  Product Specification
 
  Model No:      NT-S277
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<span>Overview &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;</span>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-277 is a type of RS-232/RS-485/RS-422 serial port fiber optic modem. It adopts industrial standard design and its wall type outface design supports DIN-rail standard lead rail installation, featuring&nbsp;easy installation. Presently many users make use of RS-232/RS-485/RS-422 serial port fiber optic modem to solve the electromagnetic interference in engineers and to extend the RS-232/RS-485/RS-422 serial port transmission distance to several or even tens of kilometers.NT-277 can provide users with RS-232/RS-485/RS-422 serial port end-to-end transparent transmission. Since signals are transmitted over fibers and these optical signals are free of electrical conductivity, they have strong anti-interference capacity and are immune to high-voltage power or thunders.
</p>
<p class="MsoNormal">
<br />
</p>
<p class="MsoNormal">
Features
</p>
<p class="MsoNormal">
Zero-Delay automatic forwarding
</p>
<p class="MsoNormal">
Supporting three types of interfaces:RS-232/485/422
</p>
<p class="MsoNormal">
Automatic detection of serial port rate judgment and control of data transmission direction
</p>
<p class="MsoNormal">
Working wavelength:850nm(multi-mode):1310nm(single mode)
</p>
<p class="MsoNormal">
Maximum communication rate:500kbps
</p>
<p class="MsoNormal">
Optional optical interfaces: SC/ST/FC
</p>
<p class="MsoNormal">
Up to 2 kilometers in multi-mode transmission and up to 40 kilometers in single mode transmission
</p>
<p class="MsoNormal">
Broad voltage inputs:5~40V DC or 85~265VAC
</p>
<p class="MsoNormal">
The interface supports 1500W surge protection and 15KV ESD protection
</p>
<p class="MsoNormal">
External power supply
</p>
<p class="MsoNormal">
<br />
</p>
<p>
<br />
</p>
<p class="MsoNormal">
Specifications
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Parameter
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Standard
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
In compliance with EIA RS-232 and RS-485 standards
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RS232 signal
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
IN ,OUT,GND
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RS-485 signal
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
D+,D-,GND
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RS-422 signal
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
R+,R-,T+,T-,GND
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Fiber Signal
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
IN,OUT
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Working mode
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Asynchronous working mode, point-to-point
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Direction control
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Adopting automatic data flow control technology, supporting automatic judgment and control of data transmission direction
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Baud rate
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
0-500Kbps,automatic detection of signal rate
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoCommentText">
Fiber wavelength
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Multi-mode:850nm;single mode:1310nm
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Transmission distance of electrical interface
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RS-232 interface:15 meters:RS-485/422 interface:1200 meters
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Transmission distance of optical interface
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Multi-mode:2KM; single mode:20KM
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Load capacity
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
RS-485/422 interface supports 32 nodes(128 nodes customizable
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Interface protection
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
600W surge protection,1500V ESD protection
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Data interface
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
8-pin connector or DB9
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Optical interface
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
FC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Dimension
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
69mm(W)*100mm(D)*22mm(H)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Operating temperature
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
-25℃ to 70℃
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Maintaining temperature
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
-40℃ to 85℃
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Humidity
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
5%-95%RH
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Input power
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
12V input
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Power Consumption
</p>
</td>
<td width="497" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
2W
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Application
</p>
<p class="MsoNormal">
<img src="http://i.bosscdn.com/product/a3/35/f8/10385ba1307fbd20f66a3e70f4.png@watermark=2&amp;color=I0ZGRkZGRg%3D%3D&amp;type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&amp;size=29&amp;p=9&amp;t=80&amp;text=bi1uZXQuYm9zc2dvby5jb20%3D" title="NT-S277" alt="NT-S277" />
</p>nnetswitch.com

  More Products from this Supplier
 
L2 managed 10/100M power over ethernet switch

L2 managed 10/100M power over ethernet switch
6 ports POE switch

6 ports POE switch
full RJ45 port industrial 10/100M switch

full RJ45 port industrial 10/100M switch
RS485/RS422/RS232 serial to ethernet converter

RS485/RS422/RS232 serial to ethernet converter
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .