  Model No:      NT-IN114D-4POE
  Country  CN
  Brand  N-net
  Packing  carton
  Minimum Order  1
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<p class="MsoNormal">
<strong>Overview</strong>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-IN114D series&nbsp;is Industrial Fast Ethernet switch equipping 4 10/100M UTP port with low-speed data port. It provides 4 10/100Base-T ports, 3 low-speed data port and 1100FX port. With strictly industrial design, it is fundamental guarantee for stability and practicability to flexible extends transmitting distance of the Ethernet and low speed data in the extreme industrial environment.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Apply NT-IN114D industrial switch equipping low-speed data port with NT-IN111D industrial media converter, the buffering of heavy traffic burst, rate smoothing of network service and remote transmission of low-speed data can perfectly resolve, having the leading feature advantage in this field.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-IN114D industrial switch can install in control cabinet by adopting optional way of DIN-RIAL or Wall mount. It is a compact product, supporting wide working temperature, redundant power input, IP40 protection, LED indicator light, being a best choice for the industrial special application and a reliable solution for your industrial Ethernet connection.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
NT-IN114D-AT&nbsp;(AF) series is adding PoE function, equipping 4 POE&nbsp;power port. No need of the power or power cable, the high definition IP camera, wireless AP, IP telephone device can be powered up by the Poe technology through a UTP. For N-net Poe unmanaged industrial switch support IEEE802.3at standard, output 25.5W.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<strong>&nbsp;</strong><strong>Features</strong>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
Built-in efficient switching core to implement flow control and reduce broadcast packets
</p>
<p class="MsoNormal">
Standard: IEEE802.3/u, 10Base-T, 100BASE-TX, IEEE802.3af, IEEE802.3at
</p>
<p class="MsoNormal">
10/100Base-TX can automatically identify the direct line and cross-line, is compatible with Various cards, switches, HUB and other Ethernet devices
</p>
<p class="MsoNormal">
It uses a store-and-forward mechanism to avoid packet loss and error frames
</p>
<p class="MsoNormal">
Provide 4 independent 10/100M Base-TX ports to UTP redundant and multi user access
</p>
<p class="MsoNormal">
Support Max up to 1552Bytes packet transmission &nbsp;
</p>
<p class="MsoNormal">
Support cut-through transmission&nbsp;and full-duplex flow control / half-duplex back pressure mode
</p>
<p class="MsoNormal">
Support 3 low-speed data port, each can set as a separated RS232,RS485 or contact closure type.
</p>
<p class="MsoNormal">
Low-speed data passage adopt Time Division Multiplexing transmit, that makes low delay and easy apply without occupy IP address.
</p>
<p class="MsoNormal">
Low-speed data port support 0-115200bps speed
</p>
<p class="MsoNormal">
Low-speed data port support multi protection from lightning, surge, overvoltage and ESD
</p>
<p class="MsoNormal">
12V to 48V DC or 24V AC Wide power input, redundant power and reverse polarity protection
</p>
<p class="MsoNormal">
Support remote power off detection and indication
</p>
<p class="MsoNormal">
-40 To 80℃&nbsp;operating temperature to meet a variety of complex environments
</p>
<p class="MsoNormal">
<span style="line-height:1.5;">IP40 protection standard housing</span>
</p>
<p class="MsoNormal">
Power port and Ethernet port supports ESD protection and EFT protection
</p>
<p class="MsoNormal">
DIN rail and panel mounting for efficient usage
</p>
<p class="MsoNormal">
Support dual-fiber multi-mode, dual-fiber single-mode and single-fiber single-mode fiber port selection, expanded the needs of users
</p>
<p class="MsoNormal">
Support POE power supply up to 25.5W for single port
</p>
<p class="MsoNormal">
7Gbps Non-blocking switching bandwidth line speed, 2K MAC address automatic learning and 16Mb Internal cache
</p>
<p class="MsoNormal">
&nbsp;&nbsp;
</p>
<p class="MsoNormal">
<strong>&nbsp;Specification</strong>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
Parameter
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&nbsp;Specifications
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Design Level
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Industrial grade IP40 design standards
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Access mode
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;10/100/1000Mbps
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Standard
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
IEEE802.3/u.10Base-T.100Base-TX.IEEE802.3af.IEEE802.3at
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Wavelength
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;1310nm/1550nm
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Transmission distance
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dual-fiber multi-mode:2 km
</p>
<p class="MsoNormal">
&nbsp;Single fiber single mode: 20/40/60/80/100 km
</p>
<p class="MsoNormal">
&nbsp;Dual-fiber single mode:20/40/60/80/100 /120 km
</p>
<p class="MsoNormal">
&nbsp;Category-5 twisted pairs: 100m
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Port
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Four RJ45 port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Connecting STP/UTP category-5 twisted pairs, EIA568A/B
</p>
<p class="MsoNormal">
&nbsp;One optical port:&nbsp;
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Multi-mode&nbsp;:SC / FC/LC(50/125, 62.5/125μm)
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;Single mode : SC / FC/LC (9/125)
</p>
<p class="MsoNormal">
&nbsp;3 low-speed data port,&nbsp;Industrial terminals, connecting to RS232,R485,contact closure according to the setting
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Conversion means
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Store and Forward mode or Time division
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Address table
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2K
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Buffer space
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Built in 16M RAM for data buffer
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Flow control
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Full duplex: flow control;
</p>
<p class="MsoNormal">
&nbsp;Half duplex: back pressure
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;BER
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&lt;10-9
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;MTBF
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;50,000 hrs
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;LED indicator
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;L/A(Link/Transmit),100M(Speed),
</p>
<p class="MsoNormal">
PWR(Power),RPF(Remote power-off),SD(Fiber signal)
</p>
<p class="MsoNormal">
D1(Data passage 1 signal),D2(Data passage 2 signal),D3(Data passage 3 signal)
</p>
</td>
</tr>
</tbody>
</table>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power supply
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power Input Range: 12 ~ 48VDC/24VAC ,
</p>
<p class="MsoNormal">
6-PIN Terminals, Redundant dual power, support power-off detection
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Power consumption
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;&lt;3W (without PSE function)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~80ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Operating humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage Temperature
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;-40~80ºC
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Storage humidity
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;5%~90% &nbsp;non-condensing
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Dimensions
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;155mm(length)×125mm(wide)×50mm(height)
</p>
</td>
</tr>
<tr>
<td width="168" valign="center" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;Weight
</p>
</td>
<td width="494" valign="top" style="border:1.0000pt solid #C0C0C0;">
<p class="MsoNormal">
&nbsp;
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<strong>Certification</strong>
</p>
<table class="MsoNormalTable" align="center">
<tbody>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMI
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC Part 15, CISPR (EN55022) class A
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMC
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;FCC,CE
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
EMS
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-2 (ESD), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-3 (RS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-4 (EFT), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-5 (Surge), Level 4
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-6 (CS), Level 3
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-8, Level 5
</p>
<p class="MsoNormal">
&nbsp;&nbsp;EN61000-4-11
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Shock
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-27
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Free Fall
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-32
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Vibration
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;IEC 60068-2-6
</p>
</td>
</tr>
<tr>
<td width="203" valign="center">
<p class="MsoNormal">
Green product
</p>
</td>
<td width="458" valign="center">
<p class="MsoNormal">
&nbsp;&nbsp;RoHS
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<strong>Application</strong>
</p>
<p class="MsoNormal">
<strong><img src="http://i.bosscdn.com/product/ad/e6/8e/5391276c4f565e9d10a4ae7f5a.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=29&p=9&t=80&text=bi1uZXQuYm9zc2dvby5jb20%3D" title="IN114D-4POE" alt="IN114D-4POE" /><br />
</strong>
</p>
</p>nnetswitch.com

  More Products from this Supplier
 
unmanaged industrial Ethernet siwtch

unmanaged industrial Ethernet siwtch
unmanaged 2 fiber POE switch

unmanaged 2 fiber POE switch
Industrial 10/100m Ethernet Poe Switch

Industrial 10/100m Ethernet Poe Switch
10G  SFP to SFP 3R repeater

10G SFP to SFP 3R repeater
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .