  <p class="1">
<p class="MsoNormal">
Our CO2 laser&nbsp;<span class="apple-converted-space">&nbsp;</span><strong>power supply</strong><span class="apple-converted-space">&nbsp;</span>has high efficiency, frequency and short response time. The
compact and handy power supply has excellent compatibility with laser device
and can be directly connected. It can take feedback interface which can be used
in closed-loop control and testing the working current of laser. With this
power supply, laser device will be easily started up and well operated with
higher conversion efficiency and longer expectation of life.
</p>
</p>
<p style="font-family:Arial, Helvetica, sans-serif;">
1) Good compatibility: It can be applicable to 80W laser tube of a number of manufacturers.
</p>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
2) Cutting Type and Sculpting Type: The cutting type has a good power stability and strong adaptability; while the sculpting type has a quick response speed and good engraving effect.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
3) Dramatically lengthen the service life of laser.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
4) Easy Control: The start and stop of laser can be easily controlled by TTL level. And there are protection switch to test the external water, ventilation, etc.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
5) Easy control of laser power: Both 0-5V analog signal and PWM signal can control the laser power.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
6) The power supply has the function of open circuit protection: Under the condition of good protective earthing, the power supply can work in open-circuit condition for a short time, which could avoid the damage of laser power supply because of the bursting of laser tube, thereby enhancing the life of power supply.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
7) The power supply can take feedback interface which can be used in closed-loop control and testing the working current of laser.
</div>
<div style="border:0px currentColor;font-family:Arial, Helvetica, sans-serif;">
8) The power supply adds a new function, that is timely scene judging which part is damaged, laser tube or laser power.
</div>
<p style="font-family:Arial, Helvetica, sans-serif;">
9) Application: Acrylic sculpture, cut; fabric sculpture, cut; Double-color plate engraving, cut; rubber sheet sculpture, cut, etc.
</p>
<p style="font-family:Arial, Helvetica, sans-serif;">
<br />
</p>
<p class="15">
&nbsp;JH80w Main parameters:
</p>
<table class="MsoNormalTable">
<tbody>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;" rowspan="4">
<p align="center" class="15">
Input
</p>
</td>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Input voltage
</p>
</td>
<td width="252" valign="center" style="border:1pt solid #000000;" colspan="2">
<p class="15">
AC220v or AC110V(Order should be specified)
</p>
</td>
</tr>
<tr>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Ac frequency
</p>
</td>
<td width="252" valign="top" style="border:1pt solid #000000;" colspan="2">
<p class="15">
47---440Hz
</p>
</td>
</tr>
<tr>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Cold surge current
</p>
</td>
<td width="121" valign="top" style="border:1pt solid #000000;">
<p class="15">
≤60A(AC220v)
</p>
</td>
<td width="131" valign="top" style="border:1pt solid #000000;">
<p class="15">
≤30A(AC110V)
</p>
</td>
</tr>
<tr>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Leakage current
</p>
</td>
<td width="121" valign="top" style="border:1pt solid #000000;">
<p class="15">
≤0.7mA(AC220V)
</p>
</td>
<td width="131" valign="top" style="border:1pt solid #000000;">
<p class="15">
≤0.4mA(AC110V)
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;" rowspan="2">
<p align="center" class="15">
output
</p>
</td>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="justify" class="15">
Maximum output voltage
</p>
</td>
<td width="252" valign="center" style="border:1pt solid #000000;" colspan="2">
<p class="15">
DC 35KV
</p>
</td>
</tr>
<tr>
<td width="178" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Maximum output current
</p>
</td>
<td width="252" valign="center" style="border:1pt solid #000000;" colspan="2">
<p class="15">
DC 35&nbsp;mA
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Efficiency
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
≥90%(Full load)
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Mean time to failure
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
≥10000&nbsp;hours
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Response speed
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
≤1mS(The switching signal is given to the time that the output current rise to 90% of the set current)
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Control interface
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
TTL&nbsp;&nbsp;Level switch control,the active level can be high or low
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Pressure
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
AC1500V 10mA 60s;
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Protect
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
Open for short time(Require the power supply housing to be well grounded,while avoiding arcing between the positive pole and the casing).
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Using environment
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
Working temperature(-10~40)℃ ,Relative humidity:≤90%
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Cooling form
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
Forced air cooling
</p>
</td>
</tr>
<tr>
<td width="132" valign="center" style="border:1pt solid #000000;">
<p align="center" class="15">
Outline size
</p>
</td>
<td width="431" valign="center" style="border:1pt solid #000000;" colspan="3">
<p class="15">
L×W×H=283*175*92(mm)
</p>
</td>
</tr>
</tbody>
</table>
<p>
<br />
</p>jhlasertube.com

  More Products from this Supplier
 
80w laser power supply

80w laser power supply
D20 Silicon reflect mirror

D20 Silicon reflect mirror
high reflectivity Si Mirror D20mm

high reflectivity Si Mirror D20mm
D30 sillicon reflect mirror

D30 sillicon reflect mirror
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .